sequence-context specific BLAST, more sensitive than BLAST, FASTA, and SSEARCH. Position-specific iterative version CSI-BLAST more sensitive than PSI-BLAST
Combining the Smith-Waterman search algorithm with the PSI-BLAST profile construction strategy to find distantly related protein sequences, and preventing homologous over-extension errors.
Protein sequence to structure alignment that includes secondary structure, structural conservation, structure-derived sequence profiles, and consensus alignment scores
A GPGPU accelerated Burrows-Wheeler transform (FM-index) short read alignment program based on BWA, supports alignment of indels with gap openings and extensions.
Explicit time and accuracy tradeoff with a prior accuracy estimation, supported by indexing the reference sequences. Optimally compresses indexes. Can handle billions of short reads. Can handle insertions, deletions, SNPs, and color errors (can map ABI SOLiD color space reads). Performs a full Smith Waterman alignment.
BLAST's nucleotide alignment program, slow and not accurate for short reads, and uses a sequence database (EST, sanger sequence) rather than a reference genome.
Uses a Burrows-Wheeler transform to create a permanent, reusable index of the genome; 1.3 GB memory footprint for human genome. Aligns more than 25 million Illumina reads in 1 CPU hour. Supports Maq-like and SOAP-like alignment policies
Quantify and manage large quantities of short-read sequence data. CASHX pipeline contains a set of tools that can be used together or as independent modules on their own. This algorithm is very accurate for perfect hits to a reference genome.
Read mapping alignment software that implements cache obliviousness to minimize main/cache memory transfers like mrFAST and mrsFAST, however designed for the SOLiD sequencing platform (color space reads). It also returns all possible map locations for improved structural variation discovery.
Accurately performs gapped alignment of sequence data obtained from next-generation sequencing machines (specifically that of Solexa/Illumina) back to a genome of any size. Includes adaptor trimming, SNP calling and Bisulfite sequence analysis.
Yes (also supports Illumina *_int.txt and *_prb.txt files with all 4 quality scores for each base)
High-quality alignment engine (exhaustive mapping, that is 100% of sensitivity, for any number of substitutions; 1 non-exhaustive indel). Several standalone applications (mapper, split mapper, mappability, and other) provided.
Complete framework with user-friendly GUI to analyse NGS data. It integrates a proprietary high quality alignment algorithm as well as plug-in capability to integrate various public aligner into a framework allowing to import short reads, align them, detect variants and generate reports. It is geared towards re-sequencing projects, namely in a diagnostic setting.
Robust, fast short-read alignment. GMAP: longer reads, with multiple indels and splices (see entry above under Genomics analysis); GSNAP: shorter reads, with a single indel or up to two splices per read. Useful for digital gene expression, SNP and indel genotyping. Developed by Thomas Wu at Genentech. Used by the National Center for Genome Resources (NCGR) in Alpheus.
Fast, accurate overlap assembler with the ability to handle any combination of sequencing technology, read length, any pairing orientations, with any spacer size for the pairing, with or without a reference genome.
iSAAC has been designed to take full advantage of all the computational power available on a single server node. As a result iSAAC scales well over a broad range of hardware architectures, and alignment performance improves with hardware capabilities
Gapped (mrFAST) and ungapped (mrsFAST) alignment software that implements cache obliviousness to minimize main/cache memory transfers. They are designed for the Illumina sequencing platform and they can return all possible map locations for improved structural variation discovery.
Fast gapped aligner and reference-guided assembler. Aligns reads using a banded Smith-Waterman algorithm seeded by results from a k-mer hashing scheme. Supports reads ranging in size from very short to very long.
Gapped alignment of single end and paired end Illumina GA I & II, ABI Colour space & ION Torrent reads.. High sensitivity and specificity, using base qualities at all steps in the alignment. Includes adapter trimming, base quality calibration, Bi-Seq alignment, and option to report multiple alignments per read.
Yes
Yes
Yes
Multi-threading and MPI versions available with paid license.
Single threaded version free for academic and non-commercial use.
NextGENe® software has been developed specifically for use by biologists performing analysis of next generation sequencing data from Roche Genome Sequencer FLX, Illumina GA/HiSeq, Life Technologies Applied BioSystems’ SOLiD™ System, PacBio and Ion Torrent platforms.
The Omixon Variant Toolkit includes highly sensitive and highly accurate tools for detecting SNPs and indels. It offers a solution to map NGS short reads with a moderate distance (up to 30% sequence divergence) from reference genomes. It poses no restrictions on the size of the reference, which, combined with its high sensitivity, makes the Variant Toolkit well-suited for targeted sequencing projects and diagnostics.
Yes
Yes
Yes
Yes
Commercial
www.omixon.com
PALMapper
PALMapper, efficiently computes both spliced and unspliced alignments at high accuracy. Relying on a machine learning strategy combined with a fast mapping based on a banded Smith-Waterman-like algorithm it aligns around 7 million reads per hour on a single CPU. It refines the originally proposed QPALMA approach.
Partek® Flow software has been developed specifically for use by biologists and bioinformaticians. It supports un-gapped, gapped and splice-junction alignment from single and paired-end reads from Illumina, Life technologies Solid TM, Roche 454 and Ion Torrent raw data (with or without quality information). It integrates powerful quality control on FASTQ/Qual level and on aligned data. Additional functionality include trimming and filtering of raw reads, SNP and InDel detection, mRNA and microRNA quantification and fusion gene detection.
Yes
Yes
Yes
Multiprocessor/Core, Client-Server installation possible
Commercial, FREE trial version
[1]
PASS
Indexes the genome, then extends seeds using pre-computed alignments of words. Works with base space as well as color space (SOLID) and can align genomic and spliced RNA-seq reads.
Indexes the genome with periodic seeds to quickly find alignments with full sensitivity up to four mismatches. It can map Illumina and SOLiD reads. Unlike most mapping programs, speed increases for longer read lengths.
Is able to take advantage of quality scores, intron lengths and computation splice site predictions to perform and performs an unbiased alignment. Can be trained to the specifics of a RNA-seq experiment and genome. Useful for splice site/intron discovery and for gene model building. (See PALMapper for a faster version).
REAL is an efficient, accurate, and sensitive tool for aligning short reads obtained from next-generation sequencing. The programme can handle an enormous amount of single-end reads generated by the next-generation Illumina/Solexa Genome Analyzer. cREAL is a simple extension of REAL for aligning short reads obtained from next-generation sequencing to a genome with circular structure.
Can map reads with or without error probability information (quality scores) and supports paired-end reads or bisulfite-treated read mapping. There are no limitations on read length or number of mismatches.
Extremely fast, tolerant to high indel and substitution counts. Includes full read alignment. Product includes comprehensive pipelines for variant detection and metagenomic analysis with any combination of Illumina, Complete Genomics and Roche 454 data.
Slider is an application for the Illumina Sequence Analyzer output that uses the "probability" files instead of the sequence files as an input for alignment to a reference sequence or a set of reference sequences.
Robust with a small (1-3) number of gaps and mismatches. Speed improvement over BLAT, uses a 12 letter hash table. SOAP2 using bidirectional BWT to build the index of reference, and it is much faster than the first version. Now an GPU-accelerated version named as SOAP3/GPU is available, that could find all 4-mismatch alignments in tens of seconds per one million reads.
For ABI SOLiD technologies. Significant increase in time to map reads with mismatches (or color errors). Uses an iterative version of the Rabin-Karp string search algorithm.
For Illumina reads. High specificity, and sensitive for reads with indels, structural variants, or many SNPs. Slow, but speed increased dramatically by using BWA for first alignment pass).
Experimental ; for singles reads only (mainly SOLiD, but with Illumina experimental support now), and with SAM native output. Highly sensitive for reads with many errors, indels (from 1 to 16), and SNPs. Uses spaced seeds. Authors recommend Shrimp2.
FPGA-accelerated reference sequence alignment mapping tool from TimeLogic. Faster than Burrows-Wheeler transform-based algorithms like BWA and Bowtie. Supports up to 7 mismatches and/or indels with no performance penalty. Produces sensitive Smith-Waterman gapped alignments.
FPGA based sliding window short read aligner which exploits the embarrassingly parallel property of short read alignment. Performance scales linearly with number of transistors on a chip (i.e. performance guaranteed to double with each iteration of Moore's Law without modification to algorithm). Low power consumption is useful for datacentre equipment. Predictable runtime. Better price/performance than software sliding window aligners on current hardware, but not better than software BWT-based aligners currently. Can cope with large numbers (>2) of mismatches. Will find all hit positions for all seeds. Single-FPGA experimental version, needs work to develop it into a multi-FPGA production version.
100% sensitivity for a reads between 15 - 240bp with practical mismatches. Very fast. Support insertions and deletions. Works with Illumina & SOLiD instruments, not 454.
^Durbin, Richard; Eddy, Sean R.; Krogh, Anders et al., eds. (1998). Biological sequence analysis: probalistic models of proteins and nucleic acids. Cambridge, UK: Cambridge University Press. ISBN 978-0-521-62971-3.[page needed]
Tags: List of sequence alignment software, Komputer Sains, 2233, Daftar/Tabel sequence alignment software This list of sequence alignment software is a compilation of software tools and web portals used in pairwise sequence alignment and multiple sequence alignment, See structural alignment software for structural alignment of proteins, Contents Database search only 2 Pairwise alignment 3 Multiple sequence alignment 4 Genomics analysis 5 Motif finding 6 Ben, List of sequence alignment software, Bahasa Indonesia, Contoh Instruksi, Tutorial, Referensi, Buku, Petunjuk unucirebon, prestasi.web.id